This printable field checklist covers moisture-control inspections for standard dry cargo containers. Mark each item as “Compliant” or “Non-compliant”; correct and recheck any non-compliance before deciding whether to load.
Inspect the container before loading

First verify the container number and inspect the roof, walls, door seals and floor. Use an inspection light in dark areas and photograph overall conditions and close-ups of defects. If there is continuous dripping, obvious standing water, holes, damaged door seals or residues unsuitable for the cargo, stop loading and contact the carrier. Laying paper or adding desiccants is no substitute for correcting the problem.
Closed-door light test: find holes and abnormal gaps

During daylight with adequate outdoor light, first open and ventilate the empty container and confirm it is safe to enter. Do not enter without assessment if there is a fumigation risk or an unidentified odor. Someone outside must supervise throughout and operate the doors, ensuring they can be opened at any moment. Never lock or seal the doors, or allow an inspector to work alone. Briefly close the doors to darken the interior and look for unusual points of light at the roof, walls, joints and door seals. Open immediately when one is found, mark the position and use an inspection light to confirm holes, cracks or seal damage. Distinguish light through normal ventilation structures from damage. No light leakage does not prove complete watertightness; still check door seals, the floor and signs of water ingress.
Priorities during Thailand’s rainy season

For example, when loading in Bo Win in September after the container truck has been through rain, carefully check the doorway, floor, waiting pallets and cartons for wetness. Website weather is for planning only; release decisions depend on actual site conditions. Even when rainfall decreases after November, inspect every container.
How to use the checklist

Keep the two inspection outcomes “Compliant / Non-compliant”; print and complete the form on site. “Compliant” for item 4 means the applicable vent treatment has been confirmed and carried out, not that vents must always be sealed. For item 14, even if the goods are not agricultural products, confirm that the consignee has an arrival inspection plan appropriate to the cargo.
Field checklist

| No. | Inspection item | Result |
|---|---|---|
| Inspect the container before loading | ||
| 1 | Check overall condition Is the container in good overall condition without obvious damage? | □ Compliant □ Non-compliant |
| 2 | Check potential water-entry points Have the walls, roof and floor been checked for holes or cracks that could admit water, with a closed-door light test where conditions permit? | □ Compliant □ Non-compliant |
| 3 | Confirm the interior is dry Is the container interior dry, without obvious standing water or damp areas? | □ Compliant □ Non-compliant |
| 4 | Confirm vent treatment requirements Confirm the vent treatment based on cargo characteristics and transport requirements. If sealing is required, first obtain the carrier’s permission, then seal temporarily from inside with removable tape or similar material without damaging the container. | □ Compliant □ Non-compliant |
| Inspect goods and packaging materials | ||
| 5 | Confirm product condition before packing Have all products reached the required dry condition before packing? | □ Compliant □ Non-compliant |
| 6 | Check pallets and packaging materials Are pallets and packaging materials dry, and were they stored indoors in a dry environment before use? | □ Compliant □ Non-compliant |
| 7 | Check storage conditions before loading Were the goods stored in a dry, sheltered warehouse before loading? | □ Compliant □ Non-compliant |
| 8 | Keep warehouse humidity records Is warehouse humidity regularly monitored and recorded, particularly during the rainy season? | □ Compliant □ Non-compliant |
| Verify desiccant selection and installation | ||
| 9 | Confirm desiccants are provided Have desiccants been provided to absorb excess moisture during transport? | □ Compliant □ Non-compliant |
| 10 | Confirm the dosage basis Has an appropriate quantity of desiccant been calculated and used based on the cargo, container size and transport duration? This checklist does not prescribe one dosage for every container; confirm it using product information and actual transport conditions. | □ Compliant □ Non-compliant |
| 11 | Confirm installation method Are the desiccants installed correctly as instructed? Has the loading team received clear installation guidance? | □ Compliant □ Non-compliant |
| 12 | Confirm desiccant type Has a suitable desiccant type been selected according to the cargo’s sensitivity to moisture? | □ Compliant □ Non-compliant |
| Arrange inspection on arrival | ||
| 13 | Notify the consignee about acceptance checks in advance Has the consignee been told to promptly check for moisture damage, mold, corrosion, unusual odors, softened packaging and other possible moisture problems after opening the container? | □ Compliant □ Non-compliant |
| 14 | Check for moisture damage that is not immediately visible For rice or other agricultural products, has the consignee been reminded that moisture damage may not appear immediately and that careful inspection is still needed after unpacking? | □ Compliant □ Non-compliant |
This checklist was compiled from relevant Absortech materials.
Field case: local damage found during inspection on 23 October 2026
During our company’s pre-loading inspection today, local container damage was found and photographed. The first image records the container number and interior; the second uses the original red circle and a pointing finger to identify the abnormal area at a joint.
Record even small defects clearly. Ask the carrier or depot to assess the finding, document any corrective work and reinspection, and then decide whether to load. These photographs show the condition when found; they do not establish that repairs or release have been completed.
Main references: TIS container climate, commodity information and the GDV packaging handbook. Thai site-inspection examples are compiled by this site.